Visual range measuring devices – Công ty Thiết bị công nghiệp và Tự động hóa AUMI - Nhà Cái W88 Casino Có Tiếng //www.w88.rentals Đại diện chính thức SICK, PERMA, PULS, MARKEM IMAJE Việt Nam Fri, 28 May 2021 07:28:41 +0000 en-US hourly 1 https://wordpress.org/?v=6.5.5 //www.w88.rentals/wp-content/uploads/2020/10/favicon.png Visual range measuring devices – Công ty Thiết bị công nghiệp và Tự động hóa AUMI - Nhà Cái W88 Casino Có Tiếng //www.w88.rentals 32 32 Visual range measuring devices VISIC620 //www.w88.rentals/en/product/sick/traffic-sensors/visual-range-measuring-devices/visual-range-measuring-devices-visic620/ //www.w88.rentals/en/product/sick/traffic-sensors/visual-range-measuring-devices/visual-range-measuring-devices-visic620/#respond Fri, 26 Feb 2021 05:50:24 +0000 //www.w88.rentals/?post_type=product&p=4817
  • Measurement of visual range for roads, tunnels, sea routes and in weather stations
  • Measured values: Standard visual range, K-value
  • Measurement principles: Scattered light forward
  • Spectral range: 640 nm ... 660 nm; Laser, protection class 2, power < 1 mW
  • Measuring ranges: 10 ... 500 m / 10 ... 16,000 m (Standard visual range)
  • Reliable measured values
  • Bài viết Visual range measuring devices VISIC620 đã xuất hiện đầu tiên vào ngày Công ty Thiết bị công nghiệp và Tự động hóa AUMI.

    ]]>
    At a glance:

    • Measurement of visual range for roads, tunnels, sea routes and in weather stations
    • Reliable measured values
    • Low operating costs
    • Low maintenance requirements due to long maintenance intervals
    • Large measuring range for visual range

    Technical data:

    • Measured values: Standard visual range, K-value
    • Measurement principles: Scattered light forward
    • Spectral range: 640 nm … 660 nm; Laser, protection class 2, power < 1 mW
    • Measuring ranges: 10 … 500 m / 10 … 16,000 m (Standard visual range)
    • Output range freely adjustable
    • Response time (t90): 2 s … 300 s
    • Accuracy: ± 5 m (For visual range below 50 m)/ ± 10 % (Of measured value for visual range below 5,000 m)/ ± 20 % (Of measured value for visual range below 16,000 m)
    • Repeatability: ± 2 % (for a visual range of 200 m)
    • Ambient temperature: –30 °C … +55 °C
    • Storage temperature: –40 °C … +75 °C
    • Ambient humidity: 0 % … 100 %
    • Electrical safety: CE
    • Enclosure rating: IP69K
    • Analog outputs: 1 output, 0 … 20 mA (Only VISIC620-1xxxx)
    • Digital outputs: 2 relay contacts, + 48 V AC, 35 W / 48 V DC, 24 W (Only VISIC620-1xxxx)
    • Digital inputs: 1 potential-free contact, + 4 V, 4.5 mA (Not with the VISIC620-1xxxx)
    • Communication interface: Serial (Only VISIC620-2xxxx)

    Type of fieldbus integration: RS-232/ RS-485

    Function: Proprietary service interface, connection to SOPAS ET software/ Proprietary service interface

    • Number: 1
    • Dimensions (W x H x D): 479 mm x 117 mm x 261 mm (for details see dimensional drawings)
    • Weight: 5.6 kg
    • Material: Stainless steel 1.4571, powder-coated
    • Power supply

    Voltage: 24

    Power consumption: ≤ 10 W

    • Test functions: Automatic self-test (contamination, drift, LED, disturbing objects)ASTRA “Guideline – Fire Detection in Road Tunnels” (2007)

    Dimensions:

    Connection diagram: