Ultrasonic – Công ty Thiết bị công nghiệp và Tự động hóa AUMI - Nhà Cái W88 Casino Có Tiếng //www.w88.rentals Đại diện chính thức SICK, PERMA, PULS, MARKEM IMAJE Việt Nam Thu, 03 Jun 2021 01:53:55 +0000 en-US hourly 1 https://wordpress.org/?v=6.5.5 //www.w88.rentals/wp-content/uploads/2020/10/favicon.png Ultrasonic – Công ty Thiết bị công nghiệp và Tự động hóa AUMI - Nhà Cái W88 Casino Có Tiếng //www.w88.rentals 32 32 Gas flow measuring instruments FLOWSIC100 //www.w88.rentals/en/product/sick/gas-flow-measuring-intruments/ultrasonic/flowsic100/ //www.w88.rentals/en/product/sick/gas-flow-measuring-intruments/ultrasonic/flowsic100/#respond Wed, 24 Feb 2021 05:40:26 +0000 //www.w88.rentals/?post_type=product&p=3516
  • Gas flow measuring instruments FLOWSIC100
  • Integrated measurement via duct diameter for types H, M, and S
  • Probe version PR for cost-saving, single-sided installation in duct
  • No purge air required for applications with gas temperatures up to 260 °C
  • Continuous emission measurement during power generation
  • Emission monitoring in waste incineration plants
  • Emission measurement in the processing industry (cement, iron and steel, glass)
  • Emission monitoring in the chemical and hydrocarbon processing (HPI) industry
  • Emission monitoring in the paper and textiles industry
  • Flow measurements and process control in e. g., heating and ventilation systems
  • Bài viết Gas flow measuring instruments FLOWSIC100 đã xuất hiện đầu tiên vào ngày Công ty Thiết bị công nghiệp và Tự động hóa AUMI.

    ]]>
    At a glance:

    • Gas flow measuring instruments FLOWSIC100
    • Rugged titanium converters for long service life
    • Corrosion-resistant material for use with aggressive gases (option)
    • Integrated measurement via duct diameter for types H, M, and S
    • Probe version PR for cost-saving, single-sided installation in duct
    • No purge air required for applications with gas temperatures up to 260 °C

    Please note: The exact device specifications and performance data of the product may deviate from the information provided here, and depend on the application in which the product is being used and the relevant customer specifications

    Technical data:

    FLOWSIC100 system

    • Measured values: Volumetric flow a. c., volumetric flow s. c., gas velocity, sound velocity, gas temperature
    • Performance-tested measurands: Gas velocity
    • Measurement principle: Ultrasonic transit time difference measurement
    • Measuring ranges:

    Gas velocity: 0 … ± 40 m/s

    Certified measuring ranges: Gas velocity 0 … 20 m/s / 0 … 40 m/s

    • Repeatability: For v < 2 m/s: ± 0.02 m/s, For v > 2 m/s: ± 1 %
    • Accuracy: ± 0.1 m/s (Depending on application)
    • Diagnostics functions: Automatic check cycle for zero and span point/ Extended device diagnosis via SOPAS ET software
    • Ambient temperature: –40 °C … +60 °C
    • Storage temperature: –40 °C … +70 °C
    • Conformities:

    2001/80/EC (13. BImSchV)

    2000/76/EC (17. BImSchV)

    27. BImSchV

    30. BImSchV

    TA-Luft (Prevention of Air Pollution)

    EN 15267

    EN 14181

    EN 1611-2

    MCERTS

    GOST

    • Electrical safety: CE

    Dimensions:

    Connection diagram:

    No tags for this post.

    Bài viết Gas flow measuring instruments FLOWSIC100 đã xuất hiện đầu tiên vào ngày Công ty Thiết bị công nghiệp và Tự động hóa AUMI.

    ]]>
    //www.w88.rentals/en/product/sick/gas-flow-measuring-intruments/ultrasonic/flowsic100/feed/ 0
    Gas flow measuring instruments FLOWSIC100 Flare //www.w88.rentals/en/product/sick/gas-flow-measuring-intruments/ultrasonic/gas-flow-measuring-instruments-flowsic100-flare/ //www.w88.rentals/en/product/sick/gas-flow-measuring-intruments/ultrasonic/gas-flow-measuring-instruments-flowsic100-flare/#respond Wed, 24 Feb 2021 05:39:39 +0000 //www.w88.rentals/?post_type=product&p=4733
  • The FLOWSIC100 Flare product family is designed for flare gas and steam flow measurements
  • Innovative sensor design for very high gas velocities and gas temperatures up to 280 °C
  • Control cycle for automatic self-diagnosis / signal optimization
  • Emissions control for accounting of CO2 emissions
  • Detection of flare gas leaks
  • Measurement of steam flow
  • Monitoring of steam injection when burning flare gas
  • Monitoring of gas losses
  • Exact mass balance and process optimization
  • Bài viết Gas flow measuring instruments FLOWSIC100 Flare đã xuất hiện đầu tiên vào ngày Công ty Thiết bị công nghiệp và Tự động hóa AUMI.

    ]]>
    At a glance:

    • Gas flow measuring instruments FLOWSIC100 Flare
    • The FLOWSIC100 Flare product family is designed for flare gas and steam flow measurements
    • High-resolution measurement and short response time
    • Innovative sensor design for very high gas velocities and gas temperatures up to 280 °C
    • Optimal signal transmission even under atmospheric pressure
    • Detached installation of the control unit up to 1,000 m away
    • Single and multi-path configuration, opt. Probe version
    • Zero point test in the field according to factory standard
    • Control cycle for automatic self-diagnosis / signal optimization
    • Emissions control for accounting of CO2 emissions
    • Detection of flare gas leaks
    • Measurement of steam flow
    • Monitoring of steam injection when burning flare gas
    • Monitoring of gas losses
    • Exact mass balance and process optimization

    Please note: The exact device specifications and performance data of the product may deviate from the information provided here, and depend on the application in which the product is being used and the relevant customer specifications

    Technical data:

    • Measured values: Gas velocity, gas temperature, gas volume and mass, Mass flow rate, molecular weight, volumetric flow a. c., volumetric flow s. c., sound velocity
    • Measurement principle: Ultrasonic transit time difference measurement
    • Hazardous area:

    1G

    2G

    3G

    Class I Division 1

    Class I Division 2

    Ga

    Gb

    Gc

    • Measuring ranges: Measuring ranges depend on nominal pipe size and gas composition
    • Gas temperature:

    Standard: –70 °C … +180 °C

    High-temperature Zone 1: –70 °C … +280 °C

    High-temperature Zone 2: –70 °C … +260 °C

    Low temperature: –196 °C … +100 °C

    Not for FLOWSIC100 EX/EX-RE Zone 1 and Class I, Division 1

    • Operating pressure: –0.5 bar (g) … 16 bar (g); FLOWSIC100 EX-S 90°: –0.5 bar (g) … 19 bar (g)
    • Nominal pipe size: 4 ″ … 72 ″, Depending on gas composition and device version
    • Enclosure rating:

    FLSE100 sender/receiver unit (ATEX zone 1): IP65, IP67

    FLSE100 sender/receiver unit (ATEX zone 2): IP65

    FLSE100 sender/receiver unit (CSA class I): depending on device version

    MCUP control unit: IP66

    MCUP control unit (19-inch version): IP20

    MCUP control unit (Ex zone 1): IP66

    MCUP control unit (Ex zone 2/Division 2): housing type 4, IP66

    • USB: ✔

    Function: Connection to SOPAS ET software

    • Serial: ✔

    Type of fieldbus integration: RS-232/ RS-485

    Function: Connection to SOPAS ET software/ Internal system bus

    • Ethernet: ✔

    Type of fieldbus integration: Via optional interface module

    • Modbus: ✔

    Type of fieldbus integration:  ASCII RS-485 (via optional interface module)/ RTU RS-485 (via optional interface module)/ TCP (via optional interface module)

    • HART: ✔

    Type of fieldbus integration:  Via optional interface module

    • PROFIBUS DP: ✔

    Type of fieldbus integration: Via optional interface module

    • Foundation Fieldbus: ✔

    Type of fieldbus integration: Via optional interface module

    Dimensions:

    Connection diagram:

    No tags for this post.

    Bài viết Gas flow measuring instruments FLOWSIC100 Flare đã xuất hiện đầu tiên vào ngày Công ty Thiết bị công nghiệp và Tự động hóa AUMI.

    ]]>
    //www.w88.rentals/en/product/sick/gas-flow-measuring-intruments/ultrasonic/gas-flow-measuring-instruments-flowsic100-flare/feed/ 0